Key features
High-level product advantages presented in a cleaner review format.
32 Physical Channels + 4 Virtual Channels
Supports up to 32 physical channels, with the option for 4 additional virtual channels.
Interchangeable Datakey™
Easy, secure programming and data management with removable Datakey™.
Real-Time Load Current Monitoring
Monitors current via iPack® 2202 switches for precise load tracking.
Field Check Monitor
Isolates ATC controller issues from load bay or wiring faults for fast troubleshooting.
Nonvolatile Event Log
Stores full intersection and voltage/current data for comprehensive diagnostics.
Signal Sequence History Log
Captures event history with 50ms resolution for detailed analysis.
Data Access via ECcom Software
Enables easy logging and configuration through ECcom.
MonitorKey® Setup Wizard
Assists with Datakey programming and initial setup.
Multiple Power Options
Operates on 48 VDC, 120 VAC, or 220 VAC depending on model.
Specifications
Dedicated technical preview for quick review.
- Function
- Cabinet monitor unit for ATC cabinets
- Channels
- Up to 32 physical load switch channels (RYG); optional four virtual channels
- Cabinet Compatibility
- ATC cabinet compatible
- Warranty
- 2 Year Limited Warranty
- Model CMUip-2212-LV
- 48 VDC (touch-safe low voltage operation in an ATC LV cabinet)
- Model CMUip-2212-HV
- 120 VAC
- Model CMUip-2212-VHV
- 220 VAC
- Load Current Monitoring
- Uses load current information from the iPack 2202 switches to detect dark intersection approaches resulting from a no-load condition at the time of the fault
- Field Check Monitor
- Analyzes the ATC output commands and field input status to isolate whether the fault was caused by an ATC malfunction or a failure in the load bay or field wiring
- Fault and Status Indicators
- POWER, 48VDC FAIL, 24VDC FAIL, 12VDC FAIL, CONFLICT, LACK OF SIGNAL, MULTIPLE, CU, LOCAL FLASH, CLEARANCE, FIELD CHECK, DIAGNOSTIC
- Serial Bus Indicators
- SB #1 RX, SB #3 RX, SB #1 ERROR, SB #3 ERROR
- Event Log
- Nonvolatile event log recording the complete intersection status as well as time stamped previous fault events, AC Line events, configuration changes, monitor resets, cabinet temperature and true RMS voltages and currents for all field inputs
- Signal Sequence History Log
- Up to 30 seconds of signal status prior to the fault trigger event, with 50ms resolution
- Datakey
- Interchangeable Datakey nonvolatile memory device; stores all CMUip-2212 configuration parameters
- MonitorKey
- EDI MonitorKey Programming Tool (includes a Parameter Setup Wizard)
- Compatible Switch Packs
- Model 2202 iPack high density switch packs
- PC Software
- EDI ECcom Windows based software for status, event log retrieval, configuration and data archival